# TR standard.

![TR standard](https://tz.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp)

Low-voltage battery

# TR standard.

Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20; IP54 optional

NOMINAL ENERGY  5.12–20.07 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://tz.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Nominal DC (V) |
| --- | --- | --- |
| TR4000WX | 5.12 | 51.2 |
| TR6000WX | 10.24 | 51.2 |
| TR8000WX | 14.336 | 51.2 |
| TR8500WX | 16.076 | 51.2 |
| TR10000WX | 20.07 | 51.2 |

Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 |
| TR6000WX | 600 × 750 × 160 / W × H × D | 95 |
| TR8000WX | 480 × 822 × 245 / W × H × D | 110 |
| TR8500WX | 480 × 822 × 245 / W × H × D | 115 |
| TR10000WX | 500 × 922 × 265 / W × H × D | 145 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C

## Coast, central plateau or highlands: make the room part of the plan.

Tanzania’s climate changes with region and elevation, and its rainfall seasons vary between regions. Match useful household storage to your daily loads, with the equipment room’s heat, moisture and service space guiding the final format.

Temperature:  Charge 0 to 55 °C

ENCLOSURE  IP20; IP54 optional

01

### Coastal home: fans, refrigeration and connectivity

In warmer coastal areas, selected fans, refrigeration and communications can form a useful planning group. A dry, sheltered utility room gives the equipment an organised setting away from daily living areas.

EU integrates the inverter and battery for a new indoor system; TR Pro supports a compatible 51.2 V inverter installation. Choose according to the circuit plan, room airflow and the exact model’s environmental limits.

Which fans, refrigeration and network devices belong on the selected circuits?

- Can rain, coastal air or condensation reach the proposed equipment position?

02

### Central home: protected storage in a dedicated room

Central areas include relatively dry climate zones. A protected utility space can support selected lights, the home office and household appliances while keeping dust and stored items away from the installation.

TR Pro offers a compact format; HP Ultra offers modular high-voltage storage when more energy is needed. Match battery voltage and communication to the inverter, then plan clear fixing, cable and service space.

How much energy is needed for the required backup hours?

- How will dust, heat and access be managed in the proposed room?

03

### Highland home: plan around the room’s temperature

Highland locations can differ from coastal conditions, and northeastern highlands have a different rainfall pattern from some central and southern regions. The actual equipment room provides the temperature and exposure inputs for selection.

A dry indoor system can serve the home-office and refrigeration plan without assuming the coast’s conditions. EU and TR Pro list charging from 0 °C; use model-specific temperature limits and retain cooling and service clearances.

What minimum and maximum room temperatures should the design cover?

- Does the proposed room remain dry through its local rainy season?

Specifications

- Start with average load and required hours to plan kWh, then check the compatible inverter’s running and starting output. More modules increase selected energy capacity within the supported system; they do not automatically increase AC output.

- EU lists IP21 for a dry indoor installation. TR Pro and HP Ultra list IP66; standard TR and HP K list IP20 with IP54 optional, and TB rack lists IP20. Assess shelter, condensation and coastal corrosion separately from the IP code.

- EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C; TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C. HP Ultra’s temperature range needs confirmation for the selected configuration; optional heating is not a general sub-zero charging claim.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized.

[![Front controls and side terminals](https://tz.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://tz.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)

Front controls and side terminals  Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet.

[![Rear bracket and terminal-side labels](https://tz.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://tz.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)

Rear bracket and terminal-side labels  Rear mounting bracket and side terminal area of the illustrated battery.

[![Circuit control switch detail](https://tz.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://tz.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)

Circuit control switch detail  Circuit control switch with ON/OFF markings.

[![Original rear three-quarter view](https://tz.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://tz.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)

Original rear three-quarter view  Rear three-quarter view showing the mounting bracket and terminal side.

[![Original side profile](https://tz.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://tz.elvorka.com/assets/product-details/tr-standard-side-profile.png)

Original side profile  Side profile showing communication ports and the recessed handle.

### Know your interfaces.

#### Power connections

Negative battery terminal  Negative DC battery power terminal as identified by the original arrow.

Positive battery terminal  Positive DC battery power terminal as identified by the original arrow.

#### Communication

Wi-Fi / Bluetooth  Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here.

Dry contact  Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied.

RS232 / CAN / RS485  Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation.

COM0 / COM1  Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits.

#### Controls & indicators

Touch screen  Touch-screen display identified in the original callout.

Running status indicator  Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified.

Alarm indicator  Alarm indication identified in the source.

SOC indicator  SOC indicator identified in the source; display thresholds are not specified.

Reset control  Reset control identified by the source; operating procedure is not given on this page.

Battery switch  Battery switch identified in the source; no switching rating is given in this callout.

#### Structure & mounting

Folding handle  Mechanical folding handle; not an electrical connector.

Wall-mounted bracket  Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here.

Rollers  Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface.

Source: Residential ESS brochure · PDF page 3 · printed pages 5-6

---

https://tz.elvorka.com/en/products/tr-standard/